CCU-100HDUSER’S MANUALMANUAL NUMBER 518452-1960Ultrak®4465 Coonpath RoadCarroll, OH 43112(800) 443-6680•(740) 756-9222•FAX (740) 756-4237CENTRALCONTR
TERM DEFINITIONSector ID Sector IDs are used for labeling specific areas that the SmartScanunit views. Up to 16 Sector IDs can be programmed and stor
SETTING UP ALARM MONITORS/VCRS4-324.4 SETTING UP ALARM MONITORS AND VCRs.The CCU can be programmed to designate monitors as alarm monitors (AM) andVCR
SETTING UP ALARM MONITORS/VCRs4-33OUTPUTS as ALARM VCR VIDEO OUTPUTS. The control outputs areused to turn the VCRs on and off.2. Enter the first vide
SAMPLE SYSTEM PROGRAMMING4-344.5 SAMPLE SYSTEM PROGRAMMINGThe following examples provide some typical situations and the methods usedfor programming t
SAMPLE SYSTEM PROGRAMMING4-351. Outline your system.SmartScan Unit (Ceiling Entrance) = Camera #2.Monitor in Office = Video Output (Monitor) #1Alarm (
SAMPLE SYSTEM PROGRAMMING4-36d. Enter 1 for Alarm VCR control output. The CCU-100 automaticallyenters a 1 for the last Alarm VCR control output becau
SAMPLE SYSTEM PROGRAMMING4-37c. Press Shift F5 on the KBD-100A keyboard.d. Type 1 for the PreShot Number and press Enter.e. Type the title of the PreS
SAMPLE SYSTEM PROGRAMMING4-38FUN NUM CAM MISC DWELL00 C AM 2 0001 C AR 2 0002 P 1 2 0.0 1003 C AA 0004ENTER FUNCTIONP,V,M,C,AMultiCall Line Definition
SAMPLE SYSTEM PROGRAMMING4-39b. Press Ac. Type 4 and press Enter.d. Next to the 4 in the MC column, type 1e. Press Enter.f. Press Esc to exit programm
SAMPLE SYSTEM PROGRAMMING4-40Perform the following steps to program the system to respond as requiredabove.1. Outline your system.Receiving Dock Camer
SAMPLE SYSTEM PROGRAMMING4-41g. Press Esc to exit programming PreShots.3. Program MultiCall 7 for alarm 5. Send camera 6 to PreShot 4, callcamera 6 t
iTABLE OF CONTENTSPageSECTION 1. INTRODUCTION ...1-11.1 DESCRIPTION.
SAMPLE SYSTEM PROGRAMMING4-4202 = Turn on Auxiliary Contact Output 103 = Send Camera Six to PreShot 4, then wait 15 seconds.04 = Turn off Auxiliary Co
4-43Table 4-2. KBD-100A KEYBOARD COMMANDSCommand DefinitionF1 "GO TO" PreShotF2 Run VectorScan OnceF3 Run VectorScan ContinuouslyF4 Run Mul
5-1SECTION 5. MAINTENANCE5.1 GENERALThis section contains the information on preventive maintenance andtroubleshooting at a user's level for the
5-2If problems still exist after verifying correct installation and the problemhas been isolated to the Central Control Unit, then it must be removed
A-1APPENDIX A. SYSTEM CONFIGURATIONA.1 GENERALPrior to programming the CCU-100, identify all pieces of equipment and theiraddresses in your specific
A-2Table A-1. AIU-100 ADDRESSINGON = 0OFF = 1AIU # Switch PositionAddress 1 2 300001100201031104001510160117111A.1.2.1 AIU-100 Cross Reference for Al
A-3A.1.3 SHB-100 ShotboxThere are sixteen possible SHB-100 addresses (0-15). The SHB-100 addressesare set using a 4-position DIP switch, S17.The foll
A-4A.1.4 Camera NumbersThe HD video switcher supports 128 cameras. The camera address and the videoinput number should be the same. The camera addres
A-5SYSTEM COMPONENTSJPD-100 ADDRESSESAddress Location Address LocationAddress Location Address LocationAIU-100 ADDRESSESAddress Alarm #’s Address Alar
iiTABLE OF CONTENTS (CONT)Page3.2 OPERATING PROCEDURE ...3-13.2.1 JPD-100 Contr
A-6MONITOR ADDRESSES (Video Output On Switcher)Address Location Address LocationVCR ADDRESSES (Video output on Switcher)Address Location Address Locat
A-7A.2 PROGRAMMING RECOMMENDATIONSThe following steps are recommended to organize the programming efforts of theSmartScan System.1. Identify and progr
A-8A.3 PROGRAMMING WORKSHEETSThe following worksheets are included to organize the programming efforts for theCCU-100.Sector Programming LogPreShot Pr
A-9SECTOR PROGRAMMING LOGPage 1 of 2This form is used to program Sector ID’s. A review of the area or the drawings coveringthese areas should be done
A-10SECTOR PROGRAMMING LOG (cont)Page 2 of 2CAMERA NUMBER ______SECTOR NAME COVERAGE6789101112131415
A-11PRESHOT PROGRAMMING LOGPage 1 of ___This form is used to program PreShots in the SmartScan units. One form or series of formscan be used for eac
A-12PRESHOT PROGRAMMING LOGPage ___ of ___CAMERA NUMBER _____PreShot # Name Coverage
A-13VECTORSCAN PROGRAMMING LOGPage ___ of ___This form is for programming VectorScans in SmartScan units. A form or series of formscan be used for ea
A-14VECTORSCAN PROGRAMMING LOGPage ___ of ___CAMERA NUMBER _____VECTORSCAN NUMBER ________DESCRIPTION ________________________________________________
A-15AIU-100 ALARM LOGPage ___ of ___This form is for assigning MultiCalls to alarm inputs and describing the system functions inthe MultiCall. There
iiiTABLE OF CONTENTS (CONT)Page4.3.7.1 JPD-100 Function Key or SHB-100 Function Key...4-204.3.8 Assigning MultiCalls to Alar
A-16AIU-100 ALARM LOGPage ___ of ___AIU # ___Alarm # MultiCall # Description of MultiCall
A-17MULTICALL LOGPage ___ of ___There can be up to 256 MultiCalls (0-255). MultiCalls can be assigned to AIU-100/AIF-100/IN Alarm Inputs, JPD-100 Qui
A-18MULTICALL LOGPage ___ of ___MultiCall # Assigned To Description
A-19MULTICALL WORKSHEETMultiCall # _____Description Assigned to (May have more than one assignment)The following table shows the required data and the
A-20MULTICALL _______FUN NUM CAM MISC DWELL00010203040506070809101112131415161718192021222324252627282930
B-1APPENDIX B. PROGRAMMING AIF-100 ALARM INPUTSB.1 GENERALThis appendix provides the programming information for the AIF-100/IN AlarmInput Auxiliary
B-2To program the alarm inputs, a MultiCall must be programmed and stored in theCCU-100 Central Control Unit; then assigned to the alarm input. To de
B-3The following display appears on the screen.PROGRAM RESPONSE TO:C > Camera/Monitor SetupA > AlarmsJ > JPD-100 JPD Quick SwQ > SHB-100 S
B-4For example, enter alarm number 25.The following display appears.NUM--MC NUM--MC NUM--MC25-- ··· 26-- ··· 27-- ···28-- ··· 29-- ··· 30-- ···31-- ··
B-5To delete MultiCalls from alarms, press the space bar until the MultiCallnumber is erased.5. Press ENTER when done assigning MultiCalls to alarms.T
ivTABLE OF CONTENTS (CONT)PageAPPENDIX B. PROGRAMMING AIF-100 ALARM INPUTS ... B-1B.1 GENERAL ...
B-6The AIF-100/CI provides the interface between the CCU-100 and the alarminputs in each of the AIF-100/AL and AIF-100/IO units connected to it. An A
B-7The alarm inputs on AIF-100/AL address 1 are AIU 0, 9 through 16. These willappear on the JPD-100 display as alarm 9 through 16.The alarm inputs o
B-82. Alarm inputs 1 through 8 on AIF-100/AL addressed as 1 are AIU 0,alarm inputs 9 through 16. These alarms will appear on the JPD-100display as al
B-9B.3.1 Assigning MultiCalls to AIF-100/AL and AIF-100/IO Alarm InputsPerform the following steps to program the alarm inputs.1. Press Shift F10 on t
B-10The alarm number entered is the first number appearing in the upperleft corner of the screen. Thirty alarm numbers appear on the screen ata time.
B-112) Press the gray page down key to move to the top of the next pageof alarms.3) Use the gray arrow keys to move to the next page or the previouspa
C-1APPENDIX C. MODEL CCU-100/HD QUICK REFERENCE GUIDECCU -100/HD OR CCU-100/HD/X CENTRAL CONTROL UNITWITH JPD-100 CONTROLLER AND KBD-100A KEYBOARDAll
C-2FUNCTION DEFINITION PROCEDUREProgram MultiCall(Continued)P = PreShotFUN NUM CAM MISC DWELLP 0-99 1-128 0-9.9 00-99V = VectorScanFUN NUM CAM MISC DW
C-3FUNCTION DEFINITION PROCEDUREProgram MultiCall(Continued)A = Auxiliary Output ControlFUN NUM CAM MISC DWELLA AUX# 1-250* 1 (ON) 00-990 (OFF)*Addres
vLIST OF TABLESTable 4-1. KEYBOARD PROGRAMMING NOTES ...4-2Table 4-2. KEYBOARD COMMANDS ...
C-4FUNCTION DEFINITION PROCEDUREStop MultiCall JPD-100 ControllerJPD-100 Function KeySHB-100 Function KeyStop All MultiCallsMCALL>3If started from
C-5FUNCTION DEFINITION PROCEDUREProgramming AlarmInputsUp to 255 alarms can beprogrammed1. Program a MultiCall for thealarm input. See Call-UpVideo
C-6FUNCTION DEFINITION PROCEDURECall-Up Video FromAlarm Inputs OnAlarm VCRProgram MultiCall to call-upvideo from alarm inputs toalarm VCR (placingfoll
C-7FUNCTION DEFINITION PROCEDUREProgrammingSHB-100 FunctionKeysUp to sixteen SHB-100s (0-15).1. Program MultiCall for eachkey.2. Assign MultiCall to F
C-8FUNCTION DEFINITION PROCEDUREMonitor Setup Position Date/Time Displayand Camera Title DisplayEnable or disable thetime/date displayEnable or disabl
1-1SECTION 1. INTRODUCTION1.1 DESCRIPTIONThis manual provides the installation, operation, programming, and maintenanceprocedures for the CCU-100/HD
1-2• SmartScan Programming PreShots, VectorScans, and Sector IDs stored in SmartScan assemblies areprogrammed using the CCU-100 Central Control Unit,
1-3 Up to eight AIU-100 units can be connected to the CCU-100 for 255 alarminputs. Up to eight AIF-100/IN units can be connected to the CCU-100 for 6
Issue 1 – November 1998Issue 1, Revision A – March 1999 – added host computer interface on COM 1, added operation andprogramming for video alarms and
1-4• Ultrak HD Series Video Switcher Interface The CCU-100/HD Central Control Unit communicates with an Ultrak HD SeriesSwitcher at COM2. The CCU s
1-5 When a video alarm occurs, the CCU starts the MultiCall assigned to the videoalarm type. The default MultiCall for all video alarm types is 000.
1-6Baud Rate: 1200, 2400, 9600, or 19.2K Baud Selectable byDIP Switch for Each Rear Panel CommunicationsPortCPU Communications: RS-232 or RS-485Full D
1-7ENVIRONMENTALTemperature Limits: 32°F to 122°F (0°C to 50°C)Humidity Limits: 0% to 95%, non-condensing
2-1SECTION 2. INSTALLATION AND INTERCONNECTIONS2.1 GENERALThis section describes the cabling requirements, DIP switch and jumper settings,the connect
2-22.2.1.1 DIP Switches (S1-S4) for Communication SettingsThe circuit board inside the CCU chassis has four DIP Switches, S1through S4, for setting th
2-3Channels 1, 3, 5, and 7Baud Rate Sn-4 Sn-51200 ON ON2400 OFF ON9600 ON OFF19.2K OFF OFFn = 1 for channel 1, n = 2 for channel 3, n = 3 for channel
2-4DIP switches S1 - S3 are be set for 9600 baud, even parity as follows:DIP Switch S1 – S3Switch Position ON/OFF1ON2OFF3ON4ON5OFF6ON7ON8ONDIP switch
2-52.2.2 JumpersThere are several jumpers on the circuit board inside the CCU chassis. Thechassis cover has to be removed to set the jumpers. These
WARNINGTHIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT,THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICHCASE THE USER MAY BE REQUIRED TO TAKE A
2-62.2.2.3 Watchdog TimerJumper W42 on the printed circuit board enables or disables the systemwatchdog timer. Jumper W42 is IN.2.2.2.4 Interrupt Jum
Figure 2-1. MODEL CCU-100/HD or CCU-100/HD/X EQUIPMENT BLOCK DIAGRAM
2-82.3.1 Model CCU-100/HD Front Panel.The CCU front panel has a connector for a JPD-100 Joystick Controller anda KBD-100A Programming Keyboard. The J
2-92.3.1.1 Front Panel Cabling Requirements• ControllerUse only the coiled cable supplied with the JPD-100 JoystickController for connection from the
2-10CONTROLLERPin 3 RX-Pin 4 5 VoltPin 5 GNDPin 6 TX-KEYBOARDPin 1 ClockPin 2 DataPin 3 ResetPin 4 GroundPin 5 5 Volt2.3.2 Model CCU-100/HD Rear Panel
2-11REAR PANEL EQUIPMENT CONNECTIONSChannel 6 RS-485 Control Data Output(FastScan, SmartScan, or CRX500Series or CRX800 Series ControlReceivers, AIF-1
2-122.3.2.2 Rear Panel Connector Pin-Out Assignmentsa. Channels One through Eight - Channels one through eight on therear panel are 6-pin DIN connecto
2-13TerminationChannel Resistor Jumper3R15W364R16W375R17W386R18W397R19W408R20W41b. COM 1 and COM 2COM 1 and COM 2 are RS-232 ports. COM 1 is for conn
2-14COM 2 PIN ASSIGNMENTSPin 2 TX Output dataPin 3 RX Input dataPin 7 GND2.3.2.3 Equipment Interconnections.The following paragraphs and illustrations
Figure 2-3. EQUIPMENT CONNECTIONS FOR CHANNELS 1, 2, AND 3NEARCLOSEOPENFAR
DECLARATION OF CONFORMITYTo The European Community Council Directive 89/336/EECISSUED BY: Ultrak®, Inc.4465 Coonpath Road NWCarroll, OH 43112USATel:
2-16• Channels 4 and 6Channels 4 and 6 are used to output the control data for theFastScan assemblies, SmartScan assemblies, and CRX500 Seriesor CRX8
Figure 2-4. EQUIPMENT CONNECTIONS FOR CHANNELS 4 AND 6
2-18• Channel 5Channel five is the interconnect for the AIU-100 Alarm InterfaceUnits and SHB-100 Shotboxes. Up to 16 units (either AIU-100s orSHB-100
Figure 2-5-1. EQUIPMENT CONNECTIONS FOR CHANNEL 5
Figure 2-5-2. EQUIPMENT CONNECTIONS FOR CHANNEL 5
Figure 2-5-3. EQUIPMENT CONNECTIONS FOR CHANNEL 5
2-22• Channels 7 and 8Channels 7 and 8 are not used.• COM 1COM 1 is for connection to a Host Computer (by others).CCU-100/HDCOM 1 TOHOSTCOMPUTERPin 2
2-23/2-24CCU-100HDCOM Port 2Ultrak HD SeriesSwitcherRJ-11 ConnectorPin 2, TX Pin 3, RXPin 7, GND Pin 4, GNDPin 3, RX Pin 5, TX2.4 INSTALLATION DRAWING
2-25
IMPORTANT SAFEGUARDS1. Read Instructions - All the safety and operating instructions should be read before the unit isoperated.2. Retain Instructions
2-26
3-1SECTION 3. OPERATION3.1 CONTROLS AND INDICATORSThe only control on the CCU is the power input selection on the rear panel. Thepower input is sele
3-2address 1 is sent out COM 2 to the video switcher. Auxiliary control data forall other addresses is sent out channels 4 and 6.a. JPD-100 Function
3-3the CCU updates all other controllers with the same monitorselected to reflect the camera change.For example:JPD-100 Controller #1 has camera #1 an
3-4If an operator calls a control camera displayed on one of theother JPD-100s in the system; the operator gets control of thecamera. The other contr
3-53.2.2 RS-485 Control Output InterfaceThe Model CCU -100 Central Control Unit sends all control data forFastScan or SmartScan assemblies and CRX-500
3-6for programming auxiliary control commands in MultiCalls. Refer to the JPD-100 Joystick Controller User’s Manual for manually switching video. The
3-7display monitor and starts the MultiCall assigned for the video alarm type.The alarm message is displayed two lines above the selected position for
3-83.2.3.1 MX-4248 I/O Module OptionThe MX-4248 I/O module has 24 alarm inputs and 8 contact outputs. Ifthe MX-4248 I/O Module is installed, the alar
3-9If a MultiCall is assigned to a specific date and time, the CCU starts theMultiCall when its internal clock reaches the programmed date and time.
13. Power Lines - An outdoor system should not be located in the vicinity of overhead power lines orother electric light or power circuits, or where i
3-10NOTEIf an alarm occurs that is disabled by anoperator at the JPD-100 Controller, the CCUdoes not respond. If an alarm occurs that isnot assigned
3-11While an alarm monitor is being used to display alarms, an operator cannotmanually switch another camera to the monitor.EXAMPLE:The alarm monitors
3-12While an alarm VCR is being used to record alarms, an operator cannotmanually switch another camera to the VCR or turn the VCR off.EXAMPLE:The ala
3-13Acknowledging AlarmsAlarms can be automatically acknowledged in the MultiCall or manuallyacknowledged on the JPD-100 Controllers. Alarms can be a
3-143.2.7 AIF-100/CO Contact Output Control InterfaceThe CCU sends all contact output control data for AIF-100/CO auxiliarycontrol devices (address 2-
3-15• Reset an AlarmWhen the CCU receives a reset alarm command, the CCU acknowledgesthe alarm and stops the MultiCall assigned to the alarm. A rese
3-16Send a SmartScan to a PreShotBitByte76543210Byte00 10100000ASCII “P” (5016)1PreShot Number (0-99)12Camera Number (1-250)23Checksum3Byte76543210Byt
3-17Reset an AlarmBitByte76543210Byte00 10100100ASCII “R” (5216)1Alarm Number (1-255)12Checksum2Byte76543210ByteBitRun a MultiCallBitByte76543210Byte0
4-1SECTION 4. PROGRAMMING4.1 ON-SCREEN HELPThe F12 function key on the KBD-100A keyboard provides an on-screen helpmenu. The menu has a brief descri
SAFETY PRECAUTIONSCAUTIONRISK OF ELECTRICSHOCK, DO NOT OPENCAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPENCOVERS. NO USER SERVICEABLE P
ON-SCREEN HELP AND PROGRAMMING NOTES4-2Shifted Key FunctionSF1 Program SmartScan OptionsSF5 Program PreShotPressing the F12 function key a fourth time
PROGRAMMING THE CCU-100/HD4-34.3 PROGRAMMING THE CCU-100/HD CENTRAL CONTROL UNITA JPD-100 Joystick Controller, a KBD-100A Keyboard, and a Diamond Seri
PROGRAMMING THE CCU-100/HD4-4Restoring Factory Default SettingsThis same jumper, W44 can be used to restore the CCUs default settings asshipped from t
DEFINING MULTICALLS4-54.3.1 Defining MultiCallsMultiCalls are used to define the CCU’s response to events such as dateand time, alarms, JPD-100 Contro
PROGRAMMING MULTICALLS4-64.3.2 List Programmed MultiCallsPerform the following steps to list the programmed MultiCalls.1. Press F11.Each time function
PROGRAMMING MULTICALLS4-7The letters of the functions that are programmable are listed at thebottom of the screen.Function Descriptions:P - PreShotV -
PROGRAMMING MULTICALLS4-85. When done entering functions, press ENTER .6. Press S to Save the MultiCall or D to Delete the MultiCall entirely. If you
PROGRAMMING MULTICALLS4-94.3.3.1 P - PreShotTo program the MultiCall to perform a PreShot, perform the followingsteps.NOTEIf the cursor does not autom
PROGRAMMING MULTICALLS4-104.3.3.2 V - VectorScanTo program the MultiCall to perform a VectorScan, perform the followingsteps.NOTEIf the cursor does no
PROGRAMMING MULTICALLS4-114.3.3.3 M - MultiCallTo program the MultiCall to perform a MultiCall (including itself), performthe following steps.NOTEIf t
HANDLING ELECTROSTATIC-SENSITIVE DEVICESATTENTIONOBSERVE PRECAUTIONSFOR HANDLINGELECTROSTATICSENSITIVEDEVICESWARNINGELECTROSTATIC SENSITIVE DEVICE. U
PROGRAMMING MULTICALLS4-124.3.3.4 C - CallThe Call function provides four system actions.1. Call a camera to a monitor2. Call a camera to an alarm mon
PROGRAMMING MULTICALLS4-131. Enter C in the FUN field.2. Enter the monitor number (1-32) in the NUM field.3. Enter the camera number (1-128) in the CA
PROGRAMMING MULTICALLS4-14C - Call (Alarm Monitor or Alarm VCR)The AM and AR functions must be the first steps in the MultiCall. Thefirst step, if bo
PROGRAMMING MULTICALLS4-15monitor or record the alarm site before acknowledging the alarm.The alarm acknowledge function can occur anywhere in theMult
PROGRAMMING MULTICALLS4-164.3.3.5 A - Auxiliary Output Control (such as VCRs)The auxiliary output control function is used to energize or de-energizer
PROGRAMMING MULTICALLS4-174. Enter 1=On or 0=Off in the MISC field.1 turns the contact on: if a normally open contact, on closes thecontact; if a nor
EDITING/DELETING MULTICALLS4-184.3.4 Editing an Existing MultiCallTo Edit a MultiCall, perform the same steps as programming a MultiCall.Use the gray
START/STOP MULTICALLS4-194.3.6 Run MultiCallA. KBD-100A KeyboardTo run a MultiCall from the KBD-100A keyboard, perform the followingsteps.1. Press fun
ASSIGNING MULTICALLS4-204.3.7.1 JPD-100 Function Key or SHB-100 Function KeyTo stop a MultiCall started from a JPD-100 Function Key or SHB-100Function
ASSIGNING MULTICALLS4-21Perform the following steps to assign MultiCalls to alarms.1. Press Shift F10.2. Press A for Alarm Inputs.3. Enter the alarm n
DEFINITIONS OF TERMSThe following terms are used often in this manual. Please become familiar withthem before programming and operating the CCU-100/H
ASSIGNING MULTICALLS4-22To delete MultiCalls from alarms, press the space bar until theMultiCall number is erased.6. Press ENTER when done assigning M
ASSIGNING MULTICALLS4-234.3.10 Assigning MultiCalls to JPD-100 Function KeysThe CCU can be programmed to assign MultiCalls to JPD-100 FunctionKeys. W
ASSIGNING MULTICALLS4-244.3.11 Assigning MultiCalls to Date and TimeA MultiCall can be assigned to Date and Time. When the clock in the CCUreaches th
ASSIGNING MULTICALLS4-25After the MultiCall is run on 12/23 at 3:00 PM, the CCU updates the starttime to reflect the next time the MultiCall is run.St
SETTING DATE AND TIME4-264.3.12 Setting the Date and Time in the CCU-100/HD Central Control UnitTo set the date and time on the clock in the CCU, perf
CAMERA AND MONITOR SETUP4-274.3.13 Camera and Monitor SetupThe Ultrak HD Video Switcher can be programmed using the CCU-100/HDor CCU-100/HD/X Central
CAMERA AND MONITOR SETUP4-28The default factory settings are as follows:1) Default camera titles (CAM xxx) and date and time displays are enabledfor a
CAMERA AND MONITOR SETUP4-29inputs that do not have video connected to them. False loss of syncalarms will be generated on video inputs with no video
CAMERA AND MONITOR SETUP4-30g. Press 7 to assign a MultiCall to a loss of sync alarm.Enter the MultiCall number (000-255) and press Enter. Thedefault
ALARM CONFIGURATIONOPTIONAL MX-4248 I/O MODULE4-314.3.14 HD Switcher MX-4248 Optional I/O ModuleThe optional MX-4248 I/O Module has 24 alarm inputs.