SAMPLE SYSTEM PROGRAMMING
4-42
02 = Turn on Auxiliary Contact Output 1
03 = Send Camera Six to PreShot 4, then wait 15 seconds.
04 = Turn off Auxiliary Contact Output 1
05 = Acknowledge Alarm 5
Lines 00 through 03 are performed simultaneously. After 15
seconds, lines 04 and 05 are performed simultaneously.
e. Press Enter.
f. Press S to Save the MultiCall.
4. Assign MultiCall 7 to Alarm #5.
a. Press Shift F10 on the KBD-100A keyboard.
b. Press A for Alarm Inputs.
c. Type 5 and press Enter.
d. Next to the 5 in the MC column, type 7
e. Press Enter.
f. Press Esc to exit programming and return to manual operation of
the system.