2-5
2.2.2 Jumpers
There are several jumpers on the circuit board inside the CCU chassis. The
chassis cover has to be removed to set the jumpers. These jumpers should
be set only by qualified technical personnel.
2.2.2.1 Enabling Channel 7 and Channel 8 or COM 1 and COM 2
Channels 7 and 8 can be jumpered so they are disabled and COM1 and
COM2 are enabled, respectively. The factory settings are in bold
typeface on the following chart.
Jumper Function Setting
W25 Enable CH7
Enable COM 1
In - Pos. 2 & 3
In - Pos. 1 & 2
W26 Enable CH7
Enable COM 1
In - Pos. 2 & 3
In - Pos. 1 & 2
W27 Enable CH8
Enable COM 2
In - Pos. 2 & 3
In - Pos. 1 & 2
W28 Enable CH8
Enable COM 2
In - Pos. 2 & 3
In - Pos. 1 & 2
2.2.2.2 Battery Backup
Jumper W44 on the printed circuit board enables or disables the back-
up battery. This jumper must be IN to enable the battery before
programming and storing data in the CCU, and to enable the clock.